| CV | Name | Positions | Values |
| 1 | Primary Address (1-127) | VVVVVVVV |
|
| 2 | Start Volts (0-255) | VVVVVVVV |
|
| 3 | Acceleration Momentum (0-255) | VVVVVVVV |
|
| 4 | Deceleration (Brake) Momentum (0-255) | VVVVVVVV |
|
| 5 | Max Volts (0-255) | VVVVVVVV |
|
| 6 | Vmid (0-255) | VVVVVVVV |
|
| 7 | Decoder Version No: | VVVVVVVV |
|
| 8 | Manufacturer ID: | VVVVVVVV |
|
| 8 | Manufacturer ID - Reset | VVVVVVVV |
|
| 9 | Back EMF Repetition Rate (0-63) | VVVVVVVV |
|
| 17 | Extended Address (0-9999) | VVVVVVVV |
|
| 19 | Consist Address (0-127) | XVVVVVVV |
|
| 19 | Consist Direction | VXXXXXXX |
- Forward
- Reversed
|
| 28 | Ch. 1 for Address | XXXXXXXV |
- Disabled
- Enabled
|
| 28 | Ch. 2 for Data | XXXXXXVX |
- Disabled
- Enabled
|
| 28 | Ch. 1 for Command Ack. | XXXXXVXX |
- Disabled
- Enabled
|
| 29 | Locomotive Direction in Forward | XXXXXXXV |
- Normal
- Reversed
|
| 29 | Speed Steps (Headlight Mode) | XXXXXXVX |
- 14
- 28/128
|
| 29 | Loco can operate on conventional DC | XXXXXVXX |
- No
- Yes
|
| 29 | Enable RailCom | XXXXVXXX |
- No
- Yes
|
| 29 | Speed Table Selection | XXXVXXXX |
- Use Vstart, Vmid, Vhigh
- Use the Speed Table
|
| 29 | Addressing Mode | XXVXXXXX |
- 2 digit addressing
- 4 digit addressing
|
| 30 | Light short-circuit | XXXXXXXV |
- Okay
- Fault
|
| 30 | Overheating | XXXXXXVX |
- Okay
- Fault
|
| 30 | Motor short-circuit | XXXXXVXX |
- Okay
- Fault
|
| 33 | F0(f) controls output A | XXXXVXXX |
- No
- Yes
|
| 34 | F0(r) controls output A | XXXXVXXX |
- No
- Yes
|
| 35 | F1 controls output A | XXXXVXXX |
- No
- Yes
|
| 36 | F2 controls output A | XXXXVXXX |
- No
- Yes
|
| 37 | F3 controls output A | XXXXVXXX |
- No
- Yes
|
| 38 | F4 controls output A | XXXXXXXV |
- No
- Yes
|
| 39 | F5 controls output A | XXXXXXXV |
- No
- Yes
|
| 40 | F6 controls output A | XXXXXXXV |
- No
- Yes
|
| 41 | F7 controls output A | XXXXXXXV |
- No
- Yes
|
| 42 | F8 controls output A | XXXXXXXV |
- No
- Yes
|
| 33 | F0(f) controls output B | XXXVXXXX |
- No
- Yes
|
| 34 | F0(r) controls output B | XXXVXXXX |
- No
- Yes
|
| 35 | F1 controls output B | XXXVXXXX |
- No
- Yes
|
| 36 | F2 controls output B | XXXVXXXX |
- No
- Yes
|
| 37 | F3 controls output B | XXXVXXXX |
- No
- Yes
|
| 38 | F4 controls output B | XXXXXXVX |
- No
- Yes
|
| 39 | F5 controls output B | XXXXXXVX |
- No
- Yes
|
| 40 | F6 controls output B | XXXXXXVX |
- No
- Yes
|
| 41 | F7 controls output B | XXXXXXVX |
- No
- Yes
|
| 42 | F8 controls output B | XXXXXXVX |
- No
- Yes
|
| 33 | F0(f) controls output C | XXVXXXXX |
- No
- Yes
|
| 34 | F0(r) controls output C | XXVXXXXX |
- No
- Yes
|
| 35 | F1 controls output C | XXVXXXXX |
- No
- Yes
|
| 36 | F2 controls output C | XXVXXXXX |
- No
- Yes
|
| 37 | F3 controls output C | XXVXXXXX |
- No
- Yes
|
| 38 | F4 controls output C | XXXXXVXX |
- No
- Yes
|
| 39 | F5 controls output C | XXXXXVXX |
- No
- Yes
|
| 40 | F6 controls output C | XXXXXVXX |
- No
- Yes
|
| 41 | F7 controls output C | XXXXXVXX |
- No
- Yes
|
| 42 | F8 controls output C | XXXXXVXX |
- No
- Yes
|
| 33 | F0(f) controls output D | XVXXXXXX |
- No
- Yes
|
| 34 | F0(r) controls output D | XVXXXXXX |
- No
- Yes
|
| 35 | F1 controls output D | XVXXXXXX |
- No
- Yes
|
| 36 | F2 controls output D | XVXXXXXX |
- No
- Yes
|
| 37 | F3 controls output D | XVXXXXXX |
- No
- Yes
|
| 38 | F4 controls output D | XXXXVXXX |
- No
- Yes
|
| 39 | F5 controls output D | XXXXVXXX |
- No
- Yes
|
| 40 | F6 controls output D | XXXXVXXX |
- No
- Yes
|
| 41 | F7 controls output D | XXXXVXXX |
- No
- Yes
|
| 42 | F8 controls output D | XXXXVXXX |
- No
- Yes
|
| 43 | F9 controls output D | XXXXXXXV |
- No
- Yes
|
| 44 | F10 controls output D | XXXXXXXV |
- No
- Yes
|
| 45 | F11 controls output D | XXXXXXXV |
- No
- Yes
|
| 46 | F12 controls output D | XXXXXXXV |
- No
- Yes
|
| 50 | Motor Type(0-5) | XXXXVVVV |
- 0
- 1
- 2
- 3
- 4
- 5
|
| 50 | EMF Switch | XXVXXXXX |
- Inactive
- Active
|
| 50 | BEMF Control | XVXXXXXX |
- On
- Off
|
| 50 | Motor Drive Frequency | VXXXXXXX |
- High
- Low
|
| 51 | Constant Braking Distance | XXXXXXXV |
- Disabled
- Enabled
|
| 51 | Automatic Braking Control | XXXXXXVX |
- Disabled
- Enabled
|
| 51 | ABC direction dependancy | XXXXXVXX |
- Enabled
- Disabled
|
| 51 | Push-Pull without Stop | XXXXVXXX |
- Disabled
- Enabled
|
| 51 | Push-Pull with Stop | XXXVXXXX |
- Disabled
- Enabled
|
| 51 | Stop on DC (RailCom off only) | XXVXXXXX |
- Disabled
- Enabled
|
| 52 | Braking Distance in Constant Mode (0-255) | VVVVVVVV |
|
| 53 | Slow approach speed with ABC (0-255) | VVVVVVVV |
|
| 54 | Push-Pull stop time (0-255 seconds) | VVVVVVVV |
|
| 55 | Dimming Intensity, Outputs A and C (0-255) | VVVVVVVV |
|
| 56 | Dimming Intensity, Outputs B and D (0-255) | VVVVVVVV |
|
| 57 | Enable dimming with F1 | XXXXXXXV |
- No
- Yes
|
| 57 | Enable dimming with F2 | XXXXXXVX |
- No
- Yes
|
| 57 | Enable dimming with F3 | XXXXXVXX |
- No
- Yes
|
| 57 | Enable dimming with F4 | XXXXVXXX |
- No
- Yes
|
| 57 | Enable dimming with F5 | XXXVXXXX |
- No
- Yes
|
| 57 | Enable dimming with F6 | XXVXXXXX |
- No
- Yes
|
| 57 | Enable dimming with F7 | XVXXXXXX |
- No
- Yes
|
| 57 | Enable dimming with F8 | VXXXXXXX |
- No
- Yes
|
| 58 | Enable Low Speed with F1 | XXXXXXXV |
- No
- Yes
|
| 58 | Enable Low Speed with F2 | XXXXXXVX |
- No
- Yes
|
| 58 | Enable Low Speed with F3 | XXXXXVXX |
- No
- Yes
|
| 58 | Enable Low Speed with F4 | XXXXVXXX |
- No
- Yes
|
| 58 | Enable Low Speed with F5 | XXXVXXXX |
- No
- Yes
|
| 58 | Enable Low Speed with F6 | XXVXXXXX |
- No
- Yes
|
| 58 | Enable Low Speed with F7 | XVXXXXXX |
- No
- Yes
|
| 58 | Enable Low Speed with F8 | VXXXXXXX |
- No
- Yes
|
| 59 | Disable momentum with F1 | XXXXXXXV |
- No
- Yes
|
| 59 | Disable momentum with F2 | XXXXXXVX |
- No
- Yes
|
| 59 | Disable momentum with F3 | XXXXXVXX |
- No
- Yes
|
| 59 | Disable momentum with F4 | XXXXVXXX |
- No
- Yes
|
| 59 | Disable momentum with F5 | XXXVXXXX |
- No
- Yes
|
| 59 | Disable momentum with F6 | XXVXXXXX |
- No
- Yes
|
| 59 | Disable momentum with F7 | XVXXXXXX |
- No
- Yes
|
| 59 | Disable momentum with F8 | VXXXXXXX |
- No
- Yes
|
| 60 | Enter the value corresponding to the desired lighting effect for B/A outputs (0-44) | VVVVVVVV |
|
| 61 | Toggle effect (outputs A/B) with F1 | XXXXXXXV |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F2 | XXXXXXVX |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F3 | XXXXXVXX |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F4 | XXXXVXXX |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F5 | XXXVXXXX |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F6 | XXVXXXXX |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F7 | XVXXXXXX |
- No
- Yes
|
| 61 | Toggle effect (outputs A/B) with F8 | VXXXXXXX |
- No
- Yes
|
| 62 | Enter the value corresponding to the desired lighting effect for D/C outputs (0-53) | VVVVVVVV |
|
| 63 | Flashing frequency for outputs C and D (255 = .13 Hz, 32 = 1 Hz, 15 = 2 Hz, 0 = 33 Hz) | VVVVVVVV |
|
| 64 | Toggle effect (outputs C/D) with F1 | XXXXXXXV |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F2 | XXXXXXVX |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F3 | XXXXXVXX |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F4 | XXXXVXXX |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F5 | XXXVXXXX |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F6 | XXVXXXXX |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F7 | XVXXXXXX |
- No
- Yes
|
| 64 | Toggle effect (outputs C/D) with F8 | VXXXXXXX |
- No
- Yes
|
| 67 | Speed Table | VVVVVVVV |
|
| 105 | User Identification #1 | VVVVVVVV |
|
| 106 | User Identification #2 | VVVVVVVV |
|
| 112 | Motor timeout on loss of DCC | VVVVVVVV |
|
| 113 | Minimum PWM (Types 4, 5 only) | VVVVVVVV |
|
| 114 | Duty Cycle (Types 4, 5 only) | VVVVVVVV |
|
| 126 | CV indicator for SUSI, offset 800 | VVVVVVVV |
|
| 127 | CV transport device for SUSI | VVVVVVVV |
|
| 128 | Decoder Software Version (read only): | VVVVVVVV |
|