Decoder Family: Lenz Gold with 6th gen BEMF

CV Definitions:

CVNamePositionsValues
1Primary Address (1-127)VVVVVVVV
    2Start Volts (0-255)VVVVVVVV
      3Acceleration Momentum (0-255)VVVVVVVV
        4Deceleration (Brake) Momentum (0-255)VVVVVVVV
          5Max Volts (0-255)VVVVVVVV
            6Vmid (0-255)VVVVVVVV
              7Decoder Version No: VVVVVVVV
                8Manufacturer ID: VVVVVVVV
                  8Manufacturer ID - ResetVVVVVVVV
                    9Back EMF Repetition Rate (0-63)VVVVVVVV
                      17Extended Address (0-9999)VVVVVVVV
                        19Consist Address (0-127)XVVVVVVV
                          19Consist DirectionVXXXXXXX
                          1. Forward
                          2. Reversed
                          28Ch. 1 for AddressXXXXXXXV
                          1. Disabled
                          2. Enabled
                          28Ch. 2 for DataXXXXXXVX
                          1. Disabled
                          2. Enabled
                          28Ch. 1 for Command Ack.XXXXXVXX
                          1. Disabled
                          2. Enabled
                          29Locomotive Direction in ForwardXXXXXXXV
                          1. Normal
                          2. Reversed
                          29Speed Steps (Headlight Mode)XXXXXXVX
                          1. 14
                          2. 28/128
                          29Loco can operate on conventional DCXXXXXVXX
                          1. No
                          2. Yes
                          29Enable RailComXXXXVXXX
                          1. No
                          2. Yes
                          29Speed Table SelectionXXXVXXXX
                          1. Use Vstart, Vmid, Vhigh
                          2. Use the Speed Table
                          29Addressing ModeXXVXXXXX
                          1. 2 digit addressing
                          2. 4 digit addressing
                          30Light short-circuitXXXXXXXV
                          1. Okay
                          2. Fault
                          30OverheatingXXXXXXVX
                          1. Okay
                          2. Fault
                          30Motor short-circuitXXXXXVXX
                          1. Okay
                          2. Fault
                          33F0(f) controls output AXXXXVXXX
                          1. No
                          2. Yes
                          34F0(r) controls output AXXXXVXXX
                          1. No
                          2. Yes
                          35F1 controls output AXXXXVXXX
                          1. No
                          2. Yes
                          36F2 controls output AXXXXVXXX
                          1. No
                          2. Yes
                          37F3 controls output AXXXXVXXX
                          1. No
                          2. Yes
                          38F4 controls output AXXXXXXXV
                          1. No
                          2. Yes
                          39F5 controls output AXXXXXXXV
                          1. No
                          2. Yes
                          40F6 controls output AXXXXXXXV
                          1. No
                          2. Yes
                          41F7 controls output AXXXXXXXV
                          1. No
                          2. Yes
                          42F8 controls output AXXXXXXXV
                          1. No
                          2. Yes
                          33F0(f) controls output BXXXVXXXX
                          1. No
                          2. Yes
                          34F0(r) controls output BXXXVXXXX
                          1. No
                          2. Yes
                          35F1 controls output BXXXVXXXX
                          1. No
                          2. Yes
                          36F2 controls output BXXXVXXXX
                          1. No
                          2. Yes
                          37F3 controls output BXXXVXXXX
                          1. No
                          2. Yes
                          38F4 controls output BXXXXXXVX
                          1. No
                          2. Yes
                          39F5 controls output BXXXXXXVX
                          1. No
                          2. Yes
                          40F6 controls output BXXXXXXVX
                          1. No
                          2. Yes
                          41F7 controls output BXXXXXXVX
                          1. No
                          2. Yes
                          42F8 controls output BXXXXXXVX
                          1. No
                          2. Yes
                          33F0(f) controls output CXXVXXXXX
                          1. No
                          2. Yes
                          34F0(r) controls output CXXVXXXXX
                          1. No
                          2. Yes
                          35F1 controls output CXXVXXXXX
                          1. No
                          2. Yes
                          36F2 controls output CXXVXXXXX
                          1. No
                          2. Yes
                          37F3 controls output CXXVXXXXX
                          1. No
                          2. Yes
                          38F4 controls output CXXXXXVXX
                          1. No
                          2. Yes
                          39F5 controls output CXXXXXVXX
                          1. No
                          2. Yes
                          40F6 controls output CXXXXXVXX
                          1. No
                          2. Yes
                          41F7 controls output CXXXXXVXX
                          1. No
                          2. Yes
                          42F8 controls output CXXXXXVXX
                          1. No
                          2. Yes
                          33F0(f) controls output DXVXXXXXX
                          1. No
                          2. Yes
                          34F0(r) controls output DXVXXXXXX
                          1. No
                          2. Yes
                          35F1 controls output DXVXXXXXX
                          1. No
                          2. Yes
                          36F2 controls output DXVXXXXXX
                          1. No
                          2. Yes
                          37F3 controls output DXVXXXXXX
                          1. No
                          2. Yes
                          38F4 controls output DXXXXVXXX
                          1. No
                          2. Yes
                          39F5 controls output DXXXXVXXX
                          1. No
                          2. Yes
                          40F6 controls output DXXXXVXXX
                          1. No
                          2. Yes
                          41F7 controls output DXXXXVXXX
                          1. No
                          2. Yes
                          42F8 controls output DXXXXVXXX
                          1. No
                          2. Yes
                          43F9 controls output DXXXXXXXV
                          1. No
                          2. Yes
                          44F10 controls output DXXXXXXXV
                          1. No
                          2. Yes
                          45F11 controls output DXXXXXXXV
                          1. No
                          2. Yes
                          46F12 controls output DXXXXXXXV
                          1. No
                          2. Yes
                          50Motor Type(0-5)XXXXVVVV
                          1. 0
                          2. 1
                          3. 2
                          4. 3
                          5. 4
                          6. 5
                          50EMF SwitchXXVXXXXX
                          1. Inactive
                          2. Active
                          50BEMF ControlXVXXXXXX
                          1. On
                          2. Off
                          50Motor Drive FrequencyVXXXXXXX
                          1. High
                          2. Low
                          51Constant Braking DistanceXXXXXXXV
                          1. Disabled
                          2. Enabled
                          51Automatic Braking ControlXXXXXXVX
                          1. Disabled
                          2. Enabled
                          51ABC direction dependancyXXXXXVXX
                          1. Enabled
                          2. Disabled
                          51Push-Pull without StopXXXXVXXX
                          1. Disabled
                          2. Enabled
                          51Push-Pull with StopXXXVXXXX
                          1. Disabled
                          2. Enabled
                          51Stop on DC (RailCom off only)XXVXXXXX
                          1. Disabled
                          2. Enabled
                          52Braking Distance in Constant Mode (0-255)VVVVVVVV
                            53Slow approach speed with ABC (0-255)VVVVVVVV
                              54Push-Pull stop time (0-255 seconds) VVVVVVVV
                                55Dimming Intensity, Outputs A and C (0-255)VVVVVVVV
                                  56Dimming Intensity, Outputs B and D (0-255)VVVVVVVV
                                    57Enable dimming with F1XXXXXXXV
                                    1. No
                                    2. Yes
                                    57Enable dimming with F2XXXXXXVX
                                    1. No
                                    2. Yes
                                    57Enable dimming with F3XXXXXVXX
                                    1. No
                                    2. Yes
                                    57Enable dimming with F4XXXXVXXX
                                    1. No
                                    2. Yes
                                    57Enable dimming with F5XXXVXXXX
                                    1. No
                                    2. Yes
                                    57Enable dimming with F6XXVXXXXX
                                    1. No
                                    2. Yes
                                    57Enable dimming with F7XVXXXXXX
                                    1. No
                                    2. Yes
                                    57Enable dimming with F8VXXXXXXX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F1XXXXXXXV
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F2XXXXXXVX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F3XXXXXVXX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F4XXXXVXXX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F5XXXVXXXX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F6XXVXXXXX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F7XVXXXXXX
                                    1. No
                                    2. Yes
                                    58Enable Low Speed with F8VXXXXXXX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F1XXXXXXXV
                                    1. No
                                    2. Yes
                                    59Disable momentum with F2XXXXXXVX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F3XXXXXVXX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F4XXXXVXXX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F5XXXVXXXX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F6XXVXXXXX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F7XVXXXXXX
                                    1. No
                                    2. Yes
                                    59Disable momentum with F8VXXXXXXX
                                    1. No
                                    2. Yes
                                    60Enter the value corresponding to the desired lighting effect for B/A outputs (0-44) VVVVVVVV
                                      61Toggle effect (outputs A/B) with F1XXXXXXXV
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F2XXXXXXVX
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F3XXXXXVXX
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F4XXXXVXXX
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F5XXXVXXXX
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F6XXVXXXXX
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F7XVXXXXXX
                                      1. No
                                      2. Yes
                                      61Toggle effect (outputs A/B) with F8VXXXXXXX
                                      1. No
                                      2. Yes
                                      62Enter the value corresponding to the desired lighting effect for D/C outputs (0-53) VVVVVVVV
                                        63Flashing frequency for outputs C and D (255 = .13 Hz, 32 = 1 Hz, 15 = 2 Hz, 0 = 33 Hz)VVVVVVVV
                                          64Toggle effect (outputs C/D) with F1XXXXXXXV
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F2XXXXXXVX
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F3XXXXXVXX
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F4XXXXVXXX
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F5XXXVXXXX
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F6XXVXXXXX
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F7XVXXXXXX
                                          1. No
                                          2. Yes
                                          64Toggle effect (outputs C/D) with F8VXXXXXXX
                                          1. No
                                          2. Yes
                                          67Speed TableVVVVVVVV
                                            105User Identification #1VVVVVVVV
                                              106User Identification #2VVVVVVVV
                                                112Motor timeout on loss of DCCVVVVVVVV
                                                  113Minimum PWM (Types 4, 5 only)VVVVVVVV
                                                    114Duty Cycle (Types 4, 5 only)VVVVVVVV
                                                      126CV indicator for SUSI, offset 800VVVVVVVV
                                                        127CV transport device for SUSIVVVVVVVV
                                                          128Decoder Software Version (read only): VVVVVVVV

                                                            This page produced by the JMRI project. SourceForge Logo