familyname=Lenz Standard manufacturer=Lenz lowVersionID=80 highVersionID=81 definitionSource=JMRI CV=1,"Primary Address (1-127)" CV=2,"Start Volts (0-255)" CV=3,"Acceleration Momentum (0-255)" CV=4,"Deceleration (Brake) Momentum (0-255)" CV=5,"Max Volts (0-255)" CV=6,"Vmid (0-255)" CV=7,"Decoder Version No: " CV=8,"Manufacturer ID: " CV=8,"Manufacturer ID - Reset" CV=9,"Back EMF Repetition Rate (0-63)" CV=17,"Extended Address (0-9999)" CV=19,"Consist Address (0-127)" CV=19,"Consist Direction,"Forward","","Reversed",""" CV=29,"Locomotive Direction in Forward,"Normal","","Reversed",""" CV=29,"Speed Steps (Headlight Mode),"14","","28/128",""" CV=29,"Loco can operate on conventional DC,"No","","Yes",""" CV=29,"Speed Table Selection,"Use Vstart, Vmid, Vhigh","","Use the Speed Table",""" CV=29,"Addressing Mode,"2 digit addressing","","4 digit addressing",""" CV=30,"Light short-circuit,"Okay","","Fault",""" CV=30,"Overheating,"Okay","","Fault",""" CV=30,"Motor short-circuit,"Okay","","Fault",""" CV=33,"F0(f) controls output A,"No","","Yes",""" CV=34,"F0(r) controls output A,"No","","Yes",""" CV=35,"F1 controls output A,"No","","Yes",""" CV=36,"F2 controls output A,"No","","Yes",""" CV=37,"F3 controls output A,"No","","Yes",""" CV=38,"F4 controls output A,"No","","Yes",""" CV=39,"F5 controls output A,"No","","Yes",""" CV=40,"F6 controls output A,"No","","Yes",""" CV=41,"F7 controls output A,"No","","Yes",""" CV=42,"F8 controls output A,"No","","Yes",""" CV=33,"F0(f) controls output B,"No","","Yes",""" CV=34,"F0(r) controls output B,"No","","Yes",""" CV=35,"F1 controls output B,"No","","Yes",""" CV=36,"F2 controls output B,"No","","Yes",""" CV=37,"F3 controls output B,"No","","Yes",""" CV=38,"F4 controls output B,"No","","Yes",""" CV=39,"F5 controls output B,"No","","Yes",""" CV=40,"F6 controls output B,"No","","Yes",""" CV=41,"F7 controls output B,"No","","Yes",""" CV=42,"F8 controls output B,"No","","Yes",""" CV=33,"F0(f) controls output C,"No","","Yes",""" CV=34,"F0(r) controls output C,"No","","Yes",""" CV=35,"F1 controls output C,"No","","Yes",""" CV=36,"F2 controls output C,"No","","Yes",""" CV=37,"F3 controls output C,"No","","Yes",""" CV=38,"F4 controls output C,"No","","Yes",""" CV=39,"F5 controls output C,"No","","Yes",""" CV=40,"F6 controls output C,"No","","Yes",""" CV=41,"F7 controls output C,"No","","Yes",""" CV=42,"F8 controls output C,"No","","Yes",""" CV=33,"F0(f) controls output D,"No","","Yes",""" CV=34,"F0(r) controls output D,"No","","Yes",""" CV=35,"F1 controls output D,"No","","Yes",""" CV=36,"F2 controls output D,"No","","Yes",""" CV=37,"F3 controls output D,"No","","Yes",""" CV=38,"F4 controls output D,"No","","Yes",""" CV=39,"F5 controls output D,"No","","Yes",""" CV=40,"F6 controls output D,"No","","Yes",""" CV=41,"F7 controls output D,"No","","Yes",""" CV=42,"F8 controls output D,"No","","Yes",""" CV=43,"F9 controls output D,"No","","Yes",""" CV=44,"F10 controls output D,"No","","Yes",""" CV=45,"F11 controls output D,"No","","Yes",""" CV=46,"F12 controls output D,"No","","Yes",""" CV=50,"Motor Type(0-5),"0 ","","1 ","","2 ","","3 ","","4 ","","5 ",""" CV=50,"EMF Switch,"Inactive","","Active",""" CV=50,"BEMF Control,"On ","","Off",""" CV=50,"Motor Drive Frequency,"High ","","Low ",""" CV=51,"Constant Braking Distance,"Disabled","","Enabled",""" CV=51,"Stop on DC (RailCom off only),"Disabled","","Enabled",""" CV=52,"Braking Distance in Constant Mode (0-255)" CV=55,"Dimming Intensity, Outputs A and C (0-255)" CV=56,"Dimming Intensity, Outputs B and D (0-255)" CV=57,"Enable dimming with F1,"No","","Yes",""" CV=57,"Enable dimming with F2,"No","","Yes",""" CV=57,"Enable dimming with F3,"No","","Yes",""" CV=57,"Enable dimming with F4,"No","","Yes",""" CV=57,"Enable dimming with F5,"No","","Yes",""" CV=57,"Enable dimming with F6,"No","","Yes",""" CV=57,"Enable dimming with F7,"No","","Yes",""" CV=57,"Enable dimming with F8,"No","","Yes",""" CV=58,"Enable Low Speed with F1,"No","","Yes",""" CV=58,"Enable Low Speed with F2,"No","","Yes",""" CV=58,"Enable Low Speed with F3,"No","","Yes",""" CV=58,"Enable Low Speed with F4,"No","","Yes",""" CV=58,"Enable Low Speed with F5,"No","","Yes",""" CV=58,"Enable Low Speed with F6,"No","","Yes",""" CV=58,"Enable Low Speed with F7,"No","","Yes",""" CV=58,"Enable Low Speed with F8,"No","","Yes",""" CV=59,"Disable momentum with F1,"No","","Yes",""" CV=59,"Disable momentum with F2,"No","","Yes",""" CV=59,"Disable momentum with F3,"No","","Yes",""" CV=59,"Disable momentum with F4,"No","","Yes",""" CV=59,"Disable momentum with F5,"No","","Yes",""" CV=59,"Disable momentum with F6,"No","","Yes",""" CV=59,"Disable momentum with F7,"No","","Yes",""" CV=59,"Disable momentum with F8,"No","","Yes",""" CV=60,"Enter the value corresponding to the desired lighting effect for B/A outputs (0-44) " CV=61,"Toggle effect (outputs A/B) with F1,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F2,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F3,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F4,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F5,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F6,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F7,"No","","Yes",""" CV=61,"Toggle effect (outputs A/B) with F8,"No","","Yes",""" CV=62,"Enter the value corresponding to the desired lighting effect for D/C outputs (0-53) " CV=63,"Flashing frequency for outputs C and D (255 = .13 Hz, 32 = 1 Hz, 15 = 2 Hz, 0 = 33 Hz)" CV=64,"Toggle effect (outputs C/D) with F1,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F2,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F3,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F4,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F5,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F6,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F7,"No","","Yes",""" CV=64,"Toggle effect (outputs C/D) with F8,"No","","Yes",""" CV=67,"Speed Table" CV=113,"Minimum PWM (Types 4, 5 only)" CV=114,"Duty Cycle (Types 4, 5 only)" CV=128,"Decoder Software Version (read only): "