<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="../XSLT/decoder.xsl"?>
<!DOCTYPE decoder-config SYSTEM "../DTD/decoder-config.dtd">

<!-- Copyright (C) JMRI 2004 All rights reserved -->
<!-- $Id: Lenz_LE1000.xml,v 1.9 2008/03/06 03:30:41 jacobsen Exp $ -->
<!--                                                                        -->
<!-- JMRI is free software; you can redistribute it and/or modify it under  -->
<!-- the terms of version 2 of the GNU General Public License as published  -->
<!-- by the Free Software Foundation. See the "COPYING" file for a copy     -->
<!-- of this license.                                                       -->
<!--                                                                        -->
<!-- JMRI is distributed in the hope that it will be useful, but WITHOUT    -->
<!-- ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or  -->
<!-- FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General Public License  -->
<!-- for more details.                                                      -->

<decoder-config>
		<version author="Paul Bednder (paul.bender@acm.org)"
			version="1" lastUpdated="20040326" />

                <!-- Version 2 - added factory reset menu items (Paul Bender) -->

<decoder>
	<family name="Lenz Value Line decoders" mfg="Lenz" 
			lowVersionID="10" highVersionID="10">
		<model model="LE1000A" numOuts="2" numFns="0"
		        nmraWarrant="yes" nmraWarrantStart="200401">
			lowVersionID="10" highVersionID="10"
		       nmraWarrant="yes" nmraWarrantStart="2004" nmraWarrantEnd="200901">
		    <size length="0.9" width=".63" height=".13" units="inches"/>
		</model>
	</family>

	<programming direct="yes" paged="yes"
	                     register="yes" ops="yes"></programming>

	<variables>

		<variable label="Primary Address" CV="1" comment="Short address"
						item="Short Address"  default="03">
			<shortAddressVal/></variable>

		<variable label="Start Volts" CV="2" item="Vstart" default="16"
				comment="Range 0-31">
			<decVal></decVal>
			</variable>

		<variable label="Accel" CV="3" default="1"
				comment="Range 0-31">
			<decVal max="31"/>
			</variable>

		<variable label="Decel" CV="4" default="1"
				comment="Range 0-31">
			<decVal max="31"/>
			</variable>

<!-- deleted max and mid voltage-->

		<variable label="Version ID" CV="7" readOnly="yes"
				item="Decoder Version" >
			<decVal/>
			</variable>

		<variable label="Manufacturer ID" CV="8" readOnly="yes"
				item="Manufacturer" default="99">
			<decVal/>
			</variable>


		<variable label="Manufacturer ID - Reset" CV="8" default="99"
                        item="Reset"
                        comment="Writing a value of 33 will reset decoder to factory defaults" >
	                <decVal/>
		</variable>

<!-- Deleted all CV 13 references-->

		<variable label="Long Address" CV="17" item="Extended Address"
		        comment="4 digit address (Range 0001-9999)">
			<longAddressVal/>
			</variable>

		<variable label="Consist Address" CV="19" mask="XVVVVVVV" item="Consist Address">
			<decVal/></variable>
		
		<variable label="Consist Direction" CV="19" mask="VXXXXXXX">
			<enumVal>
				<enumChoice choice="Normal"></enumChoice>
				<enumChoice choice="Reversed"></enumChoice>
				</enumVal></variable>

		<variable label="Normal direction of motion" CV="29"
				mask="XXXXXXXV"
		        item="Locomotive Direction">
			<enumVal>
				<enumChoice choice="Forward"/>
				<enumChoice choice="Reverse"/>
				</enumVal>
			</variable>

		<variable label="Speed Steps" CV="29" mask="XXXXXXVX"
				item="Speed Step Mode" default="1">
			<enumVal>
				<enumChoice choice="14"/>
				<enumChoice choice="28/128 (recommended)"/>
				</enumVal>
			</variable>

		<variable label="Analog conversion mode" CV="29"
				mask="XXXXXVXX" default="1"
				item="Analog (DC) Operation">
			<enumVal>
				<enumChoice choice="Off"/>
				<enumChoice choice="On"/>
				</enumVal>
			</variable>

		<variable label="Addressing Mode" CV="29" mask="XXVXXXXX"
				item="Address Format">
			<enumVal>
				<enumChoice choice="2 digit addressing"/>
				<enumChoice choice="4 digit addressing"/>
				</enumVal>
			</variable>

	<variable label="Brake Momentum on DC" CV="50" 
				item="DC Brake Momentum" mask="XXXXXVXX"
	          	comment="Governs how loco acts in DC track block">
			<enumVal>
				<enumChoice choice="Loco runs under DC analog voltage control"/>
				<enumChoice choice="Loco brakes to a stop using momentum set in CV4"/>
		        </enumVal>
			</variable>

	<variable label="Headlight Dimmed By" CV="51" mask="VVVVVVVV"
			item = "Function F0F options"
	         	comment="Controls which function dims headlight (CV 52 controls amount)">
		     <enumVal>
			<enumChoice choice="Always Dim" value="00000000"/>
			<enumChoice choice="F1" value="1"/>
			<enumChoice choice="F2" value="2"/>
			<enumChoice choice="F3" value="4"/>
			<enumChoice choice="F4" value="8"/>
			<enumChoice choice="F5" value="16"/>
			<enumChoice choice="F6" value="32"/>
			<enumChoice choice="F7" value="64"/>
			<enumChoice choice="F8" value="128"/>
		      </enumVal>
		</variable>

        <variable label="Headlight Dimming intensity" CV="52" default="255"
                        comment="Controls how much headlights dim (0-dark to 255-max bright)"
			item="Function F0F behavior">
                        <decVal min="0" max="255"/>
                        </variable>

	        <variable label="User Private ID #1" CV="105"
					item="User Id #1">
			<decVal/>
			</variable>

		<variable label="User Private ID #2" CV="106"
					item="User Id #2">
			<decVal/>
			</variable>

	<!-- Define the fixed Function-Output mapping -->
	<constant label="FL(f) controls output 1" minOut="1" default="1" /> 
	<constant label="FL(r) controls output 2" minOut="2" default="1" /> 
	</variables>

        <resets>
           <factReset label="Reset All CVs" CV="8" default="33"/>
        </resets>


</decoder>

  <pane name="Lenz">
    <column>
      <display item="Function F0F behavior" />
      <display item="Function F0F options" />
    </column> 
  </pane>